WARNINGS
· This appliance must be installed by a
qualified electrician/competent person.
Safety may be impaired if installation is
not carried out in accordance with these
instructions.
· This appliance must be earthed.
· Do not remove the screws from the earth
tab extending from the oven mains
terminal block (Fig. 1).
· Before connecting the appliance make
sure that the voltage of your electricity
supply is the same as that indicated on the
rating plate. This is situated on the lower
front frame of the appliance and can be
seen upon opening the door. Alternatively
the rating plate may also be found on the
back or top of some models (where
applicable).
· Do not alter the electrical circuitry of this
appliance.
THINGS TO NOTE
· This appliance is designed to be fitted in c abinets
of the recommended dimensions as shown
(Fig.3).
· If your cabinet interior dimension is between 565-
570mm the oven may still be fitted. However, a
minor modification to the cabinet will be required
to reduce the aperture size down to 560-565 m m,
to allow the product to be securely screwed into
the cabinet.
· The dimensions given provide adequate air
circulation around the unit within the cabinet,
ensuring compliance with BS EN60-335.
· Enquiries regarding the installation of the cooker
point, if required, should be made to your
Regional Electricity Company to ensure
compliance with their regulations.
· The appliance socket switch should be outside
the cabinet but within 2m of the appliance to
make it accessible to switch off the appli ance in
case of an emergency.
· To protect the hands, wear gloves when lifting
the oven into its housing.
Do not lift the appliance by the handles.
NOTE: HOUSE CIRCUIT
Earth leakage and continuity tests must be carried
out before the appliance is connected to the mains
supply and re-checked after fitting.