CONNECTING TO THE MAINS TERMINAL
Warning: This appliance must be earthed.
· We recommend you use a new length of 6mm2
twin core and earthed cable to ensure your
safety.
· Make connection as shown in Fig. 7 by
proceeding as follows:-
· Preform wires to the appropriate shape to suit
fitting into the mains terminal block.
· Strip inner insulation on wires using
wirestrippers.
· Twist the bared wires using pliers.
· Cut bared wires 10mm away from the end of the
inner insulation. Where uninsulated Earth wire s
are used ensure they are suitably sheathed to
leave 10mm bare wire to fit into the terminal.
· Clamp bare wires into the relevant terminal and
check they are held by tugging each one in turn.
· Clamp the mains cable securely ensuring 5mm of
the outer insulation is inside the terminal bloc k
and that the wires are not taught but not so slack
as to cause any fouling. See Fig. 7.
· Connect the remaining end to the mains cable to
the cooker point/junction box.
· Place fuse/miniature circuit breaker in circuit and
switch on at mains.
CHECKING ELECTRICAL CONNECTIONS
Confirm the appliance is correctly connected by
switching on and observing the various oven function
indicators.
NOTE: HOUSE CIRCUIT
Earth leakage and continuity tests must be carried
out before the appliance is connected to the mains
supply and re-checked after fitting.
CONNECTING TO A HOB OR COOKER
POINT
· Either follow in general terms the instructions f or
connecting to the terminal block or refer to the
hob suppliers installation instructions.
Feed the cable through the cabinet and
arrange to route the cable away from the
appliance which may become hot.
Fig.7