Ocarina/Castanet Installation Guide

Servo Control Operation

4-4

MAN-OCSRIG (Ver. 1.2)

 

 

 

 

 

 

 

 

Latch

 

 

 

 

 

Function

Option

AOK

SO1

SO2

SO3

 

 

 

 

 

 

 

10

Power up reset

No

Open

Open

Open collector

Open collector

 

 

 

collector

collector

 

 

11

Commutation failure

Yes

Open

Low

Low

Low

 

 

 

collector

 

 

 

*This indication can be used as a digital input for activating an external shunt regulator.

Table 4-1:Ocarina/Castanet Status Indications

Notes:

Without latch mode:

The status indications are reset when the fault disappears.

With latch mode:

The Short, Over Temperature and Commutation Failure status indications are reset when the enable signal is temporarily removed from the enable input.

Multiple faults:

Only the reading of the first fault is reliable. Additional faults add on to the status outputs and the indication is therefore meaningless.

Page 26
Image 26
Elmo MAN-OCSIG (Ver. 1.2) manual 1Ocarina/Castanet Status Indications