Ocarina/Castanet Installation Guide | Servo Control Operation | |
| ||
|
| |
|
|
|
|
| Latch |
|
|
|
|
| Function | Option | AOK | SO1 | SO2 | SO3 |
|
|
|
|
|
|
|
10 | Power up reset | No | Open | Open | Open collector | Open collector |
|
|
| collector | collector |
|
|
11 | Commutation failure | Yes | Open | Low | Low | Low |
|
|
| collector |
|
|
|
*This indication can be used as a digital input for activating an external shunt regulator.
Table 4-1: Ocarina/Castanet Status Indications
Notes:
Without latch mode:
The status indications are reset when the fault disappears.
With latch mode:
The Short, Over Temperature and Commutation Failure status indications are reset when the enable signal is temporarily removed from the enable input.
Multiple faults:
Only the reading of the first fault is reliable. Additional faults add on to the status outputs and the indication is therefore meaningless.