Smart Wireless THUM Adapter

00825-0100-4075, Rev BA February 2010

Hazardous Locations Certificates

North American Certifications

Factory Mutual (FM) Approvals

I5 FM Intrinsically Safe and Non-incendive

Intrinsically Safe for Class I/II/III, Division 1, Groups A, B, C, D, E, F, and G. Zone Marking: Class I, Zone 0, AEx ia llC

Temperature Codes T4 (-50 °C Tamb 70 °C) Non-incendive for Class I, Division 2, Groups A, B, C, and D.

Intrinsically safe and non-incendive when installed according to Rosemount Drawing 00775-0010.

Enclosure Type 4X/IP66

CSA - Canadian Standards Association

I6 CSA Intrinsically Safe

Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D. T3C (-50 °C Tamb 70 °C)

Intrinsically safe when installed according to Rosemount Drawing 00775-0012. Suitable for Class I, Division 2, Groups A, B, C, and D.

Enclosure Type 4X/IP66

European Certifications

I1 ATEX Intrinsic Safety

Certificate No.: Baseefa09ATEX0125X II 1G Ex ia IIC T4 (-50 °C Tamb 70 °C)

IP66

1180

Table 2. Input Parameters

Loop Power

Ui = 30V

Ii = 200 mA

Pi = 1.0 W

Ci = 0

Li = 0

Special conditions for safe use (X)

The surface resistivity of the antenna is greater than one gigaohm. To avoid electrostatic charge build-up, it must not be rubbed or cleaned with solvents or a dry cloth.

The enclosure is made of aluminium alloy and given a protective polyurethane paint finish; however, care should be taken to protect it from impact or abrasion if located in a zone 0.

N1 ATEX Type n

 

Certificate No.: Baseefa09ATEX0131

II 3 G

Ex nA IIC T4 (-50 °C Tamb 70 °C)

 

Ui = 45 Vdc MAX

 

IP66

 

1180

 