Emerson 1F95-391 manual Cool Fast, Optional Remote Temperature Sense, Configuration

Models: 1F95-391

1 44
Download 44 pages 44.49 Kb
Page 11
Image 11
Cool Fast.

Cool Fast.

(User menu, Step 11) This feature, when set to ON, will bring the second stage of cooling on any time you manually lower the temperature three or more degrees below room tempera- ture. If COOL FAST is set to OFF, the thermostat will delay the second stage from 0 to 30 minutes based on how well the first stage is keeping up with your setting.

Optional Remote Temperature Sense.

(User menu, Step 12,13,14,15) Up to three remote sensors (F145-1328) can be attached to this thermostat to sense indoor temperature at locations away from the thermostat. Each sensor may be located as far as 300 feet away from the thermostat. This is an excellent feature if the thermostat is in a poor location for sensing temperature or if

you want to install the thermostat in a separate room to prevent tampering. After installing and connecting the remote sensor(s) to the thermostat, the installer can enable each remote indoor temperature sensor (A, B, and/or C). When operating with remote sensor(s), the thermostat will calculate an average of the sensed temperatures in all enabled sensor locations (A, B, C and/or L), then display the average temperature as the room temperature. The temperature at each remote sensor can be displayed by pressing the light button twice within one second. With the thermostat in program run or hold mode. Temperatures at the outdoor and indoor remote sensors will be displayed with subsequent presses of the light button in the following order (if connected): outdoor sensor, sensor L, A, B, C. You can also assign each sensor different priorities during

9

different program periods. This allows the system to maintain a comfortable environment by giving higher priority to occupied locations. At the same time, giving lower priority to unoccu- pied locations enhances efficient system operation. EXAMPLE: Your home has bedrooms on the upper level and a guest bedroom on the main level, along with the living room, kitchen, etc. The thermostat (sensor L) is located in the hall on the main level. Remote sensors are located on the upper level (sensor A) and the guest bedroom (sensor B). The lower level would be occupied in the DAY

and EVE periods. The upper level would be occupied in the NHT and MOR periods. With no guest in the guest bedroom, the sensors could be programmed as follows: