Thermostat Setting and

SYMPTOM

POSSIBLE CAUSE

CORRECTIVE ACTION

Thermostat Setting and

1. Thermostat thermometer setting

The thermostat can be adjusted +/- 5°F. See the

Thermostat Thermometer

requires adjustment.

Temperature Display Adjustment in the Operating

Disagree

 

Manual under configuration.

 

 

 

Thermostat Does Not Follow

1. AM or PM set incorrectly in

Check current clock and program settings including

Program

program.

the AM or PM designations for each time period. If a

 

2.AM or PM set incorrectly on the

voltage spike or a static discharge occurs use the

 

clock.

Reset Operation listed above.

 

3. Voltage spike or static discharge.

 

 

 

 

Blank Display and/or Keypad

1. Voltage spike or static discharge.

Check heat/cool system for proper operation. If a

Not Responding

 

voltage spike occurs, use the Reset Operation by

 

 

pressing FAN, TIME BACK , and the temperature

 

 

arrow at the same time.

 

 

 