Emerson 1F95-391 manual FAQs

Models: 1F95-391

1 44
Download 44 pages 44.49 Kb
Page 33
Image 33
Manual background

FAQs

 

1F95-391

 

 

 

 

 

 

 

 

 

 

 

15. How do I temporarily

 

Any time your program is running and you would like to override it for a specific amount

Override the program and

 

of time, press

or

until the temperature you want is displayed. The display will

Hold Til Timing?

 

indicate HOLD, and the number of hours remaining in the hold period will be indicated

 

 

 

with the word HRS. To adjust the length of time for the override, press TIME FWD or

 

 

 

TIME BACK. The time you select will become the new number of hours for the Hold Til

 

 

 

timing. Once your time is selected, let the thermostat revert back to normal operation on its

 

 

 

own to accept the change.

 

 

 

 

 

 

 

16. What is the

 

Many furnaces have safety devices that shut the system down when a lock-out condition

thermostat Click Test?

 

occurs in the furnace. If the thermostat is turned off or the call for heat is cancelled (by

 

 

 

lowering and then raising the set temperature) the furnace may start operating again. A

 

 

 

diagnostic to see if the thermostat is operating when the room temperature is below the

 

 

 

thermostat setting (in heat) is to lower the setting below the room temp. Within about 3

 

 

 

seconds the thermostat should make a soft click sound. This sound is the thermostat turning

 

 

 

off the call for heat and usually indicates the thermostat is operating properly. If the

 

 

 

thermostat does not click you would be suspicious of the thermostat and try resetting it by

 

 

 

following it’s reset operation. If the thermostat does not click after being reset contact your

 

 

 

heating and cooling service person or place of purchase for a replacement. If the thermostat

 

 

 

clicks and the heat works intermittently contact the furnace manufacturer or local service

 

 

 

person. They will want to observe the condition when it is not working.

 

 

 

 

 

31

 

 

 

 

 

 

 

FAQs

Page 33
Image 33
Emerson 1F95-391 manual FAQs