FAQs |
|
| |
|
| ||
|
|
| |
3. My furnace (air condi- |
| The | |
tioning) cycles too fast |
| Anticipation) that allows you to increase or decrease the cycle times in heating and cooling. | |
(slow). Is there an adjust- |
| This is useful if you think your cycle times are too long or too short. The higher the number | |
ment? |
| you select, the longer the cycle. The lower the number you select, the shorter the cycle. The | |
|
| ||
|
| adjustment for HEATING is from 1 to 40. The factory Preset is 05, the range of adjustment | |
|
| for COOLING is from 9 to 40. The factory Preset is 24. The cooling will not go below 9 | |
|
| because compressors require a longer cycle. See page 6 of your Installation Instructions. | |
|
|
| |
4. Why does the blower fan |
| Normally the blower will turn off within a few minutes after the call for heat or cool. The | |
keep running after the |
| blower running after the system shuts off may indicate (1) the thermostat is set to FAN ON, | |
system has shut off? |
| (2) the fan has been programmed to run at that time period or (3) something has damaged the | |
|
| thermostat or equipment. If the thermostat display indicates FAN ON, press the fan button | |
|
| once to set it to FAN AUTO, meaning the fan will cycle only with the equipment. If the | |
|
| display indicates PRG FAN (Program Fan), sometime during programming, the FAN | |
|
| button was pushed. To remove PRG FAN (Program Fan), check all of the programmed | |
|
| times and temperatures. When you encounter PRG FAN, press the FAN | button to |
|
| remove it from that time period in the program. As a final test, set the thermostat to OFF. | |
|
| Verify that FAN ON or FAN AUTO is not displayed. If the fan continues to run, you may | |
|
| want to contact your heating and cooling service person for assistance. |
|
|
|
|
|