User Configuration Menu (Continued) |
| |||
7 | TIME | FWD | (F) | C |
8 | TIME | FWD | SET FAN | 0 HRS (OFF) to |
|
|
| (0) | 6 HRS |
Adjusts temperature display between F or C | 8 |
Set Fan (one shot) option. Set the duration of the | 8 |
one shot option. |
|
9 | TIME | FWD |
10TIME FWD
11TIME FWD
12TIME FWD
13TIME FWD
14TIME FWD
15TIME FWD
BEEP | OFF |
(ON) |
|
HEAT FAST | OFF |
(ON) |
|
COOL FAST | OFF |
(OFF) |
|
REMT SEN A | ON |
(OFF) |
|
REMT SEN B | ON |
(OFF) |
|
REMT SEN C | ON |
(OFF) |
|
STAT SEN L | OFF |
(ON) |
|
Turns beeper ON or OFF. | 8 |
ON allows second stage to energize if setpoint is raised | 8 |
3 or more degrees. OFF (economy) minimizes second |
|
stage operation on setpoint changes. |
|
ON allows second stage to energize if setpoint is | 9 |
lowered 3 or more degrees. OFF (economy) minimizes |
|
second stage operation on setpoint changes. |
|
Enables Remote Sensor A (connected to SA). | 9&10 |
Enables Remote Sensor B (connected to SA). | 9&10 |
Enables Remote Sensor C (connected to SA). | 9&10 |
OFF Disables Thermostat Sensor. (Only available if | 9&10 |
remote sensor A, B, or C is connected). |
|