Emerson I/O Wiring - Model 2400S Analog Transmitters, Hazardous area, Safe area, Rload COUNTER

Models: 2400S

1 50
Download 50 pages 13.6 Kb
Page 28
Image 28
Rload COUNTER

I/O Wiring – Model 2400S Analog Transmitters

Figure 3-17Hazardous area frequency/discrete output wiring using galvanic isolator

Hazardous area

Safe area

External power supply

Vout

Rload

COUNTER

Galvanic isolator

Figure 3-18Hazardous area frequency/discrete output wiring using barrier with external load resistance

Hazardous area

Safe area

Vout

Rbarrier

Rload COUNTER

Rbarrier

Vin

Note: Rbarrier and Rload should be added together to determine the proper Vin. Refer to Figure 3-19.

24

Micro Motion® Model 2400S Transmitters

Page 28