Model 2400S Analog (Zone 1 Exi)

Dimensions and Specifications

Model 2400S Analog (Zone 1 Exi)

Channel A

One passive 4–20 mA output

Intrinsically safe

Isolated to ±50 VDC from all other outputs and earth ground

Maximum load limit: 820 ohms

Can report mass flow, volume flow, density, temperature, or drive gain

Output is linear with process from 3.8 to 20.5 mA, per NAMUR NE43 (June 1994)

Channel B (configurable)

One passive 4–20 mA output

Intrinsically safe

Isolated to ±50 VDC from all other outputs and earth ground

Maximum load limit: 820 ohms

Can report mass flow, volume flow, density, temperature, or drive gain

Output is linear with process from 3.8 to 20.5 mA, per NAMUR NE43 (June 1994)

One passive frequency/pulse output

Intrinsically safe

Can report mass flow or volume flow, which can be used to indicate flow rate or total

Scalable to 10,000 Hz

Power: External (passive): +36 VDC maximum, +24 VDC typical

Output is linear with flow rate to 12,500 Hz

One passive discrete output

Intrinsically safe

Can report five discrete events, flow switch, forward/reverse flow, calibration in progress, or fault

Power: External (passive): +36 VDC maximum, +24 VDC typical

Maximum sink capability: 500 mA

One passive discrete input

Intrinsically safe

Power: External (passive): +3 to 36 VDC maximum

Can reset all totals, reset mass total, reset volume total, or start sensor zero

Entity parameters

 

 

 

Value

 

 

 

 

Frequency/

 

Parameter

4–20 mA output

discrete output

 

 

 

 

 

 

Voltage (Ui)

36 V

36 V

 

 

 

 

 

 

Current (Ii)

500 mA

500 mA

 

 

 

 

 

 

Power (Pi)

1.5 W

1.5 W

 

 

 

 

 

 

Capacitance (Ci)

1.1 nF

1.1 nF

 

 

 

 

 

 

Inductance (Li)

0.0 mH

0.0 mH

 

 

 

 

Model 2400S PROFIBUS-DP

Digital 2-way PROFIBUS-DP signal.

 

 

 

Certified by PNO.

 

 

 

 

 

 

 

Model 2400S DeviceNet

Digital 2-way DeviceNet signal.

 

 

 

Certified by ODVA.

 

 

 

 

 

 

 

 

Specifications