2.4Field hydrostatic pressure testing
The Daniel 3818 LNG Liquid Ultrasonic Flow Meter can be
The liquid ultrasonic meter pressure containing parts include but are not limited to the transducer housings. These pressure containing parts are pressure tested while attached to the meter body as a completed ultrasonic meter assembly.
The hydrostatic test is verification of the pressure containing capability of the liquid ultrasonic meter pressure containing parts and the seals that seal them. Perform a visual inspection of the meter and visually inspect the meter and leak test the flanges.
LEAKAGE OR PRESSURE CONTAINING PARTS FAILUREUse precautions to eliminate hazards to personnel in the event of leakage or failure of the liquid ultrasonic meter pressure containing parts or failure of the test equipment and to prevent
Failure to do so may result in injury to personnel or cause damage to the equipment.
Field hydrostatic pressure testing | 21 |