Daniel 3818 LNG Liquid Ultrasonic Meter Installation Manual

Section 4: Configuring a 3818 LNG Meter

3-9000-771 Rev A

May 2012

 

 

 

AMS Device Manager - Manual Setup

Use the Manual Setup wizard to configure the meter’s parameters. See Figure 4-4and Figure 4-5and from the AMS Device Manager Configure menu click Manual Setup.

Figure 4-10 AMS Device Manager - Configure Manual Setup

Procedure

1.If installed, remove security wires from the endcap and the Bracket/Cover hex head bolts that secures the Base Enclosure.

1.Disable the Write Protect switch in the CPU Module to write any of the following configuration parameters to your meter.

2.Click the Device Variables Mapping tab. The Primary and Secondary variables are read only and are configured for Uncorrected Flow Rate. The Third and Fourth variable configuration choices include Pressure and Temperature.

3.Click the Units tab (see AMS Device Manager - Guided Setup, Step 1).

4.Click the Analog Output 1 (HART) tab (see AMS Device Manager - Guided Setup, Step 2a.).

5.Click the Analog Output 2 tab. Follow the configuration instructions in the AMS Device Manager - Guided Setup, Step 2b. The read only Secondary variable Content, Uncorrected Flow Rate, displays. Use the drop-down arrow and select the (flow) Direction - Forward or Reverse. Enter a Lower and Upper Range limit. Set the Alarm Action parameters. Click Apply, after you enter the data to write the parameters to the meter.

Using AMS Device Manager to configure the meter

69