Electrical Specifications

Electrical Specifications

7.0ELECTRICAL SPECIFICATIONS

Table 5

Electrical data—50 Hz systems

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reheat Options

 

 

Electric

 

None

 

 

Electric

 

None

 

 

 

 

 

 

 

 

 

Humidifier Options

 

 

IR/SGH

 

IR/SGH

Steam or None

Steam or None

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Models

Motor HP

Volts

200

230

380-415

200

230

380-415

200

230

380-415

200

230

380-415

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CW026

2.0

FLA

46.7

43.4

24.3

19.8

17.2

 

9.9

33.9

32.3

17.9

7.0

6.1

 

3.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.0

FLA

49.8

46.1

25.9

22.9

19.9

 

11.5

37.0

35.0

19.5

10.1

8.8

 

5.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CW038

3.0

FLA

62.9

59.0

33.2

22.9

19.9

 

11.5

50.1

47.9

26.8

10.1

8.8

 

5.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.0

FLA

68.6

63.9

36.0

28.6

24.8

 

14.3

55.8

52.8

29.6

15.8

13.7

 

7.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CW041

3.0

FLA

62.9

59.0

33.2

22.9

19.9

 

11.5

50.1

47.9

26.8

10.1

8.8

 

5.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5.0

FLA

68.6

63.9

36.0

28.6

24.8

 

14.3

55.8

52.8

29.6

15.8

13.7

 

7.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CW051

5.0

FLA

94.6

88.4

49.6

41.2

35.9

 

20.7

69.2

66.2

36.8

15.8

13.7

 

7.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7.5

FLA

103.9

96.5

54.2

50.5

44.0

 

25.3

78.5

74.3

41.4

25.1

21.8

 

12.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CW060

5.0

FLA

107.9

101.4

56.8

41.2

35.9

 

20.7

82.5

79.2

44.0

15.8

13.7

 

7.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7.5

FLA

117.2

109.5

61.4

50.5

44.0

 

25.3

91.8

87.3

48.6

25.1

21.8

 

12.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CW076

7.5

FLA

126.6

122.6

68.6

50.5

44.0

 

25.3

101.2

100.4

55.8

25.1

21.8

 

12.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10.0

FLA

131.7

128.4

71.2

55.6

49.8

 

27.9

106.3

106.2

58.4

30.2

27.6

 

15.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CW084

7.5

FLA

126.6

122.6

68.6

50.5

44.0

 

25.3

101.2

100.4

55.8

25.1

21.8

 

12.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10.0

FLA

131.7

128.4

71.2

55.6

49.8

 

27.9

106.3

106.2

58.4

30.2

27.6

 

15.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10.0

FLA

131.7

128.4

71.2

55.6

49.8

 

27.9

106.3

106.2

58.4

30.2

27.6

 

15.1

CW106

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15.0

FLA

147.1

142.4

78.9

71.0

63.8

 

35.6

121.7

120.2

66.1

45.6

41.6

 

22.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20.0

FLA

161.5

152.8

86.1

85.4

74.2

 

42.8

136.1

130.6

73.3

60.0

52.0

 

30.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10.0

FLA

131.7

128.4

71.2

55.6

49.8

 

27.9

106.3

106.2

58.4

30.2

27.6

 

15.1

CW114

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15.0

FLA

147.1

142.4

78.9

71.0

63.8

 

35.6

121.7

120.2

66.1

45.6

41.6

 

22.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20.0

FLA

161.5

152.8

86.1

85.4

74.2

 

42.8

136.1

130.6

73.3

60.0

52.0

 

30.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.FLA = FULL LOAD AMPS

2.Amperage requirements are based on the rated max FLA current of each component in the unit. The rated max FLA current of the unit is not the sum total of all components, but is the total of the components which operate during maximum electrical load conditions.

3.The values in the table are for power demand of the unit only.

4.Units are 3-phase, 50-cycle.

5.Consult factory engineering department for electrical requirements of units with variations not listed above.

Table 6

Indoor evaporator fan motor electrical requirements—50Hz systems

 

 

 

 

 

 

Hp

Volts

200

230

380-415

 

 

 

 

 

 

 

2.0

FLA

7.0

6.1

3.5

 

 

 

 

 

 

 

3.0

FLA

10.1

8.8

5.1

 

 

 

 

 

 

 

5.0

FLA

15.8

13.7

7.9

 

 

 

 

 

 

 

7.5

FLA

25.1

21.8

12.5

 

 

 

 

 

 

 

10.0

FLA

30.2

27.6

15.1

 

 

 

 

 

 

 

15.0

FLA

46.2

42.0

24.2

 

 

 

 

 

 

 

20.0

FLA

NA

NA

30.0

 

 

 

 

 

 

 

1.Refer to General Data Section for standard fan motor size on units.