Overview of DFE-Diamond Module Shutdown Procedure
4-6 Troubleshooting
Recommended Shutdown Procedure Using OFFLINE/RESET SwitchBeforepullingaDFE‐Diamondmoduleoutofachassis,
pressortaponitsOFFLINE/RESETswitchforlessthan1second.
ItsCPULEDchangesfromsolidgreentoblinkingbetweengreenandamber,indicatingthatthe
DFE‐Diamondmoduleisshuttingdown.Attheendoftheshutdownroutine,theCPULED
changestoa67%/33%sequenceofamber/off,respectively,indicatingthatthemoduleisinahalt
state.AtthistimeitissafetorestartorremovetheDFE‐Diamondmodulefromthechassis.
WhenacontrolledshutdownisinitiatedfromtheOFFLINE/RESETswitch,youhave60seconds
fromthetimetheCPUstartsflashingamber/offuntilthetimethedeviceisautomatically
restarted.
Figure 4-2 OFFLINE/RESET Switch
1OFFLINE/RESET switch
Caution: Do not pull any DFE-Diamond module out of an operating chassis before it has completed
its shutdown routine.
Precaución: No retire los módulos DFE-Platinum del chasis en funcionamiento hasta que no se
haya terminado con la rutina de apagado.
Note: The only safe time to pull a DFE-Diamond module out of the chassis is when the CPU LED is
blinking amber. Otherwise, system operation will be interrupted.