| Using LANVIEW |
|
| Table |
|
| ||
|
|
|
|
|
|
| LED | Color | State | Recommended Action |
|
|
|
|
|
|
|
| CPU | Off | Power disconnected. | If the LED remains off after connecting AC |
|
|
|
|
| power or DC power from an RPS, check |
|
|
|
|
| the following: |
|
|
|
|
| 1. Make sure there is power at the power |
|
|
|
|
| source (AC source and RPS if |
|
|
|
|
| applicable). |
|
|
|
|
| 2. Replace the power cord with a known |
|
|
|
|
| good one or check the continuity of the |
|
|
|
|
| power cord. |
|
|
|
|
| 3. If the SecureStack A2 still does not |
|
|
|
|
| power up, the system may have a fatal |
|
|
|
|
| error. Contact Enterasys Networks for |
|
|
|
|
| technical support. |
|
|
|
|
|
|
|
|
| Red | Solid. | If the LED remains red for several |
|
|
|
|
| minutes, the system may have a fatal |
|
|
|
|
| error. Contact Enterasys Networks for |
|
|
|
|
| technical support. |
|
|
|
|
|
|
|
|
|
| Blinking. Diagnostics have | Contact Enterasys Networks for technical |
|
|
|
| failed. | support. |
|
|
|
|
|
| |
|
| Amber | Solid. Diagnostics are running. If the LED remains amber for more than |
| |
|
|
|
| several minutes, contact |
|
|
|
|
| Enterasys Networks for technical support. |
|
|
|
|
|
|
|
|
|
| Blinking. Code image is being | None. |
|
|
|
| downloaded, or the Manager |
|
|
|
|
| switch is copying its |
|
|
|
|
| configuration to the other |
|
|
|
|
| members in the stack (this |
|
|
|
|
| happens automatically every |
|
|
|
|
| 15 minutes and every time the |
|
|
|
|
| “save config” command is |
|
|
|
|
| executed. |
|
|
|
|
|
|
|
|
|
| Green | Solid. System is fully | None. |
|
|
|
| functional. |
|
|
|
|
|
|
|
|
|
|
| Blinking. | None. |
|
SecureStack A2 Installation Guide