Using LANVIEW

Table 4-1 LANVIEW LEDs (continued)

LED

Color State

Recommended Action

 

 

 

DOWN

Off

No valid connection to switch

 

 

stackup connector.

1.Make sure the switch connected to the stackup connector is powered on.

2.Replace cable with a known good one.

3.If the problem still exists, contact Enterasys Networks for technical support.

 

Green

Solid. Valid connection to

None.

 

 

switch stackup connector.

 

 

 

Flashing. Information is being

 

 

 

transferred via the stacking

 

 

 

cable.

 

 

 

 

 

UP

Off

No valid connection to switch

1. Make sure the switch connected to the

 

 

stackdown connector.

stackdown connector is powered on.

 

 

 

2. Replace cable with a known good one.

 

 

 

3. If the problem still exists, contact

 

 

 

Enterasys Networks for technical

 

 

 

support.

 

 

 

 

 

Green

Solid. Valid connection to

None.

 

 

switch stackdown connector.

 

 

 

Flashing. Information is being

 

 

 

transferred via the stacking

 

 

 

cable.

 

 

 

 

 

Manager

Off

Switch is operating as a

None.

 

 

Member in the stack.

 

 

 

 

 

 

Green

Solid. Switch is operating as

None.

 

 

the Manager of the stack.

 