Using ATX Trunking
•helddown — trunking is enabled, but the trunk connection has been rejected. Indicates that an error has been detected and the link is being held out of service until the error condition clears. After a short
•broken — the port has been configured for trunking, but is physically non- operational.
Rmt Bridge Id
Displays the MAC address portion of the remote bridge’s bridge ID.
NOTE |
The Rmt Bridge Id field can be used to determine which ports belong to which trunk group. Ports in the same trunk group will have the same remote bridge ID.
Rmt IP Address
Displays the remote bridge’s IP address.
Last Error
Displays the reason for failure when the link is in a helddown state. Reasons for failure include:
•(1) none — no error; the trunking protocol may restart with no error conditions when trunking is activated for a port or when the MIB variable that controls extra trunk groups is modified.
•(2)
•(3)
•(4)
•(5) standby — the trunk group is filled to capacity with other ports; this port is now a hot standby. If another port leaves the trunk group, this port will then be included in the group.
•(6)
•(7)
•(8)
The Port Trunking Window |