Wireless Switch Configuration Tasks

quickstart Command Procedure

To run the quickstart command:

1.Using the null modem cable shipped with the RBT‐8100, attach a PC to the RoamAbout wireless switch’s serial console port. Use these modem settings:

9600 bps, 8 bits

1 stop

No parity

Hardware flow control disabled

Note: Do not attempt to connect a monitor, keyboard, or mouse to the switch. Use only a null modem cable connected to the serial console port.

2.Press Enter three times, to display a username prompt (Username:), a password prompt (Password:), and then a command prompt such as the following:

RBT-8110-aabbcc>

(Each switch has a unique system name that contains the model number and the last half of the switch’s MAC address.)

3.Access the enabled level (the configuration level) of the CLI:

RBT-8110-aabbcc> enable

4.Press Enter at the Enter password prompt.

5.Type quickstart. The command asks you a series of questions. You can type ? for more help. To quit, press Ctrl+C. The following example code accepts the defaults for system name and country code, and does not configure SSIDs, user information, or distributed access points.

RBT-8110-aabbcc# quickstart

This will erase any existing config. Continue? [n]: y

Answer the following questions. Enter '?' for help. ^C to break out System Name [RBT-8110]:RBT-8110-aabbcc

Country Code [US]: US

System IP address []: 182.29.1.250

System IP address netmask []: 255.255.255.0

Default route []: 182.29.1.1

Do you need to use 802.1Q tagged ports for connectivity on the default VLAN? [Y/N]: y

Specify the port number that needs to be tagged [1-2, <CR> ends config]: 2 Specify the tagged value for port [2] [<CR> ends config:] 100

Specify the port number that needs to be tagged [1-2, <CR> ends config]: Enable WebView [y]: y

Admin username [admin]: rbtadmin

Admin password [mandatory]: letmein

Enable password [optional]: enable

Do you wish to set the time? [y]: y

Enter the date (dd/mm/yy) []: 31/03/06

Is daylight saving time (DST) in effect [n]: n

Enter the time (hh:mm:ss) []: 04:36:20

Enter the timezone []: EST

Enter the offset (without DST) from GMT for 'PST' in hh:mm [0:0]: -5:00

Do you wish to configure wireless? [y]: y

Enter a clear SSID to use: public

RBT-8110 Wireless Switch Installation Guide 3-3

Page 27
Image 27
Enterasys Networks RBT-8110 manual Quickstart Command Procedure