Specifications

CLEARANCES TO COMBUSTIBLES - 1700 FREESTANDING:

MAINTAIN THESE MINIMUM CLEARANCES TO UNSHIELDED COMBUSTIBLES*

 

���� ����

 

 

����

 

 

��������

 

��������

�����

 

 

 

 

 

�������� ����

 

 

�����

 

 

������

 

������ ���� ����

����

 

����

 

 

������

 

 

�����

 

 

 

 

I

J

������

Figure 8: 1700 Freestanding Clearance to Combustibles

 

 

Single Wall Pipe

Double Wall Pipe**

Double Wall Pipe

Top vent out back

 

 

 

 

with Heat Efficiency

wall with min. 48”

 

 

 

 

Shield 50-1088 (Flat

(1220 mm) vertical

 

 

 

 

top model only)

rise; double wall

 

 

 

 

 

 

A

From side wall

20”

13”

13”

11”

to side of unit

(508 mm)

(330 mm)

(330 mm)

(279 mm)

 

 

 

 

 

 

 

B

From rear wall

12”

10”

7”

13”

to back of unit

(305 mm)

(254 mm)

(178 mm)

(330 mm)

 

 

 

 

 

 

 

C

From adjacent wall

10”

81⁄2”

6”

 

to corner of unit

(254 mm)

(216 mm)

(152 mm)

 

 

 

 

 

 

 

 

 

D

From side wall

29”

22”

22”

20”

to collar

(737 mm)

(559 mm)

(559 mm)

(508 mm)

 

 

 

 

 

 

 

E

From rear wall

15”

13”

10”

16”

to collar

(381 mm)

(330 mm)

(254 mm)

(406 mm)

 

 

 

 

 

 

 

F

From adjacent wall

181⁄2”

17”

141⁄2”

 

to collar

(470 mm)

(432 mm)

(368 mm)

 

 

 

 

 

 

 

 

 

G

† From door opening

USA 16” (406 mm)

USA 16” (406 mm)

USA 16” (406 mm)

USA 16” (406 mm)

to edge of hearth pad

CND 18” (450 mm)

CND 18” (450 mm)

CND 18” (450 mm)

CND 18” (450 mm)

 

 

 

 

 

 

 

H

† From side/back of unit

USA 6” (152 mm)

USA 6” (152 mm)

USA 6” (152 mm)

USA 6” (152 mm)

to edge of hearth pad

CND 8” (200 mm)

CND 8” (200 mm)

CND 8” (200 mm)

CND 8” (200 mm)

 

 

 

 

 

 

 

Alcove (48” Deep)

 

 

 

 

 

 

 

 

 

 

I

Total Width

 

51” (1295 mm)

 

 

 

 

 

 

 

 

J

Total Height

 

72” (1829 mm)

 

 

 

 

 

 

 

 

K

Top of stove to ceiling

 

44” (1118 mm)

 

 

 

 

 

 

 

 

L

Side wall to stove

 

13” (330 mm)

 

 

 

 

 

 

 

 

M

Side wall to pipe

 

22” (559 mm)

 

 

 

 

 

 

 

 

N

Back wall to unit

 

8” (203 mm)

 

 

 

 

 

 

 

 

O

Back wall to pipe

 

11” (279 mm)

 

 

 

 

 

 

 

 

CAUTION: An uninsulated smoke pipe must not pass through an attic, roof space, closet or similar concealed space, or through a floor, ceiling, wall, or partition, or any combustible construction.

FLOOR PROTECTION: If a stove is installed on a combustible floor, it must have a pedestal or leg kit with ash pan attached and be on a NON-COMBUSTIBLE hearth pad

*ALL CLEARANCES CAN BE REDUCED WITH SHIELDING ACCEPTABLE TO THE LOCAL AUTHORITY. **DOUBLE WALL:

IN CANADA: Any ULC-S629 listed chimney system with the accompanying listed double wall vent connector.

IN U.S.A.: Any UL 103 HT listed chimney system with the accompanying listed double wall vent connector.

15

Page 15
Image 15
Enviro C-11116, 1700 Insert, 1200 Insert, 1700 Fireplace Freestanding owner manual Freestanding Clearance to Combustibles