Installation
Figure 36: Leveling leg. |
Figure 35: Attaching removable flue.
SURROUND PANEL SEALED INSTALLATION FOR USA ONLY - INSERT:
Before starting this type of installation
refer to INSTALLATION - MASONRY FIREPLACE INSTALLATION - INSERT for additional
information. For clearances refer to
SPECIFICATIONS - CLEARANCES TO COMBUSTIBLES
-1200 INSERT and SPECIFICATIONS - CLEARANCES TO COMBUSTIBLES - 1700 INSERT.
1.Before the face plate is installed onto the unit, glue a 6” (150mm) wide R20 fiberglass insulation strip around the perimeter of the back of the panels using RTV silicon or stove gasket cement. When the face plate is installed onto the unit the insulation must overlaps the fireplace opening to form a seal between the masonry fireplace and the unit’s face plate. Let the silicon or cement dry.
2.To make the installation of the surround panel onto the unit easy have the unit 6” (150mm) out from the fireplace,
3.Push the insert into the fireplace, allowing the insulation to form a seal between the panels and the fireplace. Tuck any exposed insulation behind the face plate.
����� �� ��� ���� ���� �� ������������ �� |
��������� ���� ������� ���� � ������� |
��������������� ���� �� �� ��� � ������� �� |
��� ������ ����� �� �� �� ��� ������ ���� ����� |
���� ������� ��� ��� ���� ���������� ���� |
��� ��� ��������� �� ������� ������������� |
�������� ������������� ��� ���� ��������� |
�� ������� ��� �� ��� ������� �� ������ �������� |
�� �������� |
Damper Removed |
or Fastened Open |
Mantel |
Insulation Around the |
Back of the Face Plate |
Surround Panel |
USA 16” (406 mm) |
CND 18” (450 mm) |
Masonry Fireplace |
Figure 37: Installation with Surround Sealed.