Installation

OUTSIDE AIR KIT:

It is mandatory to use outside air for installations in mobile homes.

A 4” (10.2 cm) fresh air adaptor kit is available. This adaptor can be installed either on the back pedestal or through the floor under the pedestal. The cover plate must be installed on the unit if your stove is located in a mobile home or if using outside air from the bottom.

Place the 1⁄4” mesh screen between the fresh air adaptor and the body of the pedestal (as shown to right).

NOTE: Fresh air connection to the unit must be a non-combustible pipe, example: 4” (10.2 cm) single wall aluminum flex pipe.

���� �� ��������

Figure 19: Fresh Air Adaptor onto the Back of the Pedestal.

NOTE: Remove the cover plate on the rear of the pedestal if room air is to be used for combustion air.

RECOMMENDED HEIGHTS FOR FLUE PIPE:

The minimum flue pipe height at sea level is 12 feet (3.7 m) straight up from top of the unit. For every 1000 feet (305 m) above sea level, 4% must be added to the overall height. Use Tables 7, 8, and 9 to calculate the required vertical rise required.

Table 9: Recommended Height for Flue Pipe.

Elevation

 

Minimum recommended flue pipe height for # of elbows

above sea

 

(Note: No more than 2 offsets (4 elbows) can be used. 2x45°=1x90°

level

 

 

 

 

 

 

 

 

feet

0

 

2 x 15°

4 x 15°

2 x 30°

4 x 30°

2 x 45°

4 x 45°

0-1000

12.0

 

12.7

13.3

13.3

14.7

14.0

16.0

1000-2000

12.5

 

13.2

13.8

13.8

15.3

14.6

16.6

2000-3000

13.0

 

13.7

14.4

14.4

15.9

15.1

17.3

3000-4000

13.4

 

14.2

14.9

14.9

16.5

15.7

17.9

4000-5000

13.9

 

14.7

15.4

15.4

17.1

16.2

18.6

5000-6000

14.4

 

15.2

16.0

16.0

17.6

16.8

19.2

6000-7000

14.9

 

15.7

16.5

16.5

18.2

17.4

19.8

7000-8000

15.4

 

16.3

17.0

17.0

18.8

17.9

20.5

8000-9000

15.8

 

16.8

17.6

17.6

19.4

18.5

21.1

9000-10000

16.3

 

17.3

18.1

18.1

20.0

19.0

21.8

meters

0

 

2 x 15°

4 x 15°

2 x 30°

4 x 30°

2 x 45°

4 x 45°

0-305

3.7

 

3.9

4.1

4.1

4.5

4.3

4.9

305-610

3.8

 

4.0

4.2

4.2

4.6

4.4

5.1

610-915

4.0

 

4.2

4.4

4.4

4.8

4.6

5.3

915-1220

4.1

 

4.3

4.6

4.6

5.0

4.8

5.5

1220-1525

4.2

 

4.5

4.7

4.7

5.2

4.9

5.7

1525-1830

4.4

 

4.6

4.9

4.9

5.4

5.1

5.9

1830-2135

4.5

 

4.8

5.0

5.0

5.5

5.3

6.0

2135-2440

4.7

 

4.9

5.2

5.2

5.7

5.5

6.2

2440-2745

4.8

 

5.1

5.4

5.4

5.9

5.6

6.4

2745-3050

5.0

 

5.3

5.5

5.5

6.1

5.8

6.6

Table 10: Distance to add to

overall vertical height.

 

Distance to add

 

 

 

Part used

feet

meters

 

 

 

45° elbow

1.0

0.3

 

 

 

90° elbow

2.0

0.6

 

 

 

“T”

3.0

0.9

 

 

 

1 foot

 

 

(0.3m) of

2.0

0.6

horizontal

 

 

run

 

 

 

 

 

Table 11: Examples of calculating overall vertical height required.

 

Height

 

 

sea level with 2

13.3 ft (4.1 m)

x 30° elbows

 

 

 

one “T”

3.0 ft (0.9 m)

 

 

11⁄2 ft (0.6 m)

3.0 ft (0.9 m)

horizontal run

 

 

 

Total 1

19.3 ft (5.9 m)

 

 

 

 

4000-5000 ft

 

(1220-1525 m)

13.9 ft (4.2 m)

above sea level

 

 

 

one “T”

3.0 ft (0.9 m)

 

 

2 ft (0.6 m)

4.0 ft (1.2 m)

horizontal run

 

Total 2

20.9 ft (6.3 m)

 

 

23

Page 23