OPTIONAL FAN INSTALLATION - FREESTANDING:

Refer to FAN WIRING DIAGRAM before installing your optional fan

kit.

1.Remove the fan assembly from the box and inspect for any damage to the assembly. If damage is noticed call your dealer, distributor or courier company and have components replaced before installing kit.

2.Remove the knock out at the bottom of the back panel of the appliance by using a flat head screwdriver as a lever, hook the tip of the screwdriver under the panel beside the tabs and push the panel out.

3.Install two (2) T-20 screws into the top two (2) holes. Place the blower assembly over these two (2) screws.

4.Ensure the temperature sensor will touch the unit when mounted. If it does not touch, adjust the sensor so it does. Tighten the two (2) top screws and install the two (2) bottom screws and tighten.

5.Plug the fan assembly in and check for proper operation.

FAN REMOVAL - INSERT:

Figure 49: Back View of Freestanding

Unit with Fan Kit.

The fan kit is pre-installed into the left shroud that comes with your unit. If a decorative set of shroud plates is purchased, the fan assembly must be removed from the shroud to installed the decorative plates (refer to “REMOVAL

OF THE SHROUDS - INSERT”).

1) Disconnect all electrical connections for the fan kit.

2) Remove the four (4) T-20 screws that hold the fan mounting plate to the shroud. If the fan needs to be removed from its mounting plate, use a 1⁄4” socket and wrench to remove the six (6) bolts holding the fan housing to the plate.

3) Remove the fan control knob and nut from the front of the shroud and pull the controls out the back.

4) Slide the plug out the front of the shroud.

5) Install the fan kit into the new shroud by following steps 1 through 4 in reverse order. Refer to FAN WIRING DIAGRAM to ensure the fan is reconnected properly.

Figure 50: Insert Unit with Fan.