Installation

 

and in any area within 10 feet

 

 

 

Rain cap/

(304.8 cm) of the roof ridge,

 

 

 

 

 

 

Spark arrestor cap

 

 

 

 

 

 

 

 

 

 

 

the chimney must be 2 feet

 

 

Roof radiation

Storm Collar

(60.9

cm)

above

the

ridge.

 

 

Roof flashing

Refer to Figure 24.

 

 

 

shield (if required)

 

 

 

 

 

Roof

Note:

Increasing

the

chimney

 

 

 

 

Insulated chimney

 

height above the roof may

 

 

help your unit to draft better.

 

 

 

 

This greater draft can decrease

 

 

 

 

problems

such

 

as

difficult

Ceiling

Minimum

Minimum air space

start-ups, smoke

coming out

 

18" (475 mm)

 

in accordance with

when door is open, and dirty

 

 

 

chimney manufacturer.

 

 

 

 

glass. You may initially try

 

 

 

Insulated corner

the minimum required height

 

 

 

and if problems do arise, add

 

 

 

 

additional height later.

 

 

 

Chimney

Wall support

10. Slide the

roof

flashing

over

 

 

connector

Chase

your chimney and seal the

 

 

 

 

 

 

(optional)

flashing to the

roof

with a

Woodstove

Optional

 

roofing compound. Secure the

fan

 

 

 

 

roof flashing to your roof with

 

 

 

 

nails or screws.

 

 

 

 

 

Pedestal

 

 

11. Place the storm collar over the

Hearthpad

 

 

flashing and seal the joints

 

 

 

 

with silicone caulking.

 

 

 

 

 

 

12. Fasten

the

rain

cap

/

spark

Floor

Outside air connection

 

arrestor cap to the top of your

 

 

through wall or floor

 

chimney.

 

 

 

 

 

Figure 26: Standard Horizontal Installation.

13. Place

the

stove

back

into

 

 

 

 

position.

 

 

 

 

 

 

 

 

 

14.Install the chimney connector pipe with the lower (crimped) edge of the pipe inside the flue collar. Any creosote formed will then run back down into the stove. All connections must be tight and secured with three sheet metal screws equally spaced. Double wall pipe is recommended over single wall.

15.Also install an outside air flex pipe to the stove.

IMPORTANT: When a metal prefabricated chimney is used, the manufacturer’s installation instructions must be followed. You must also purchase and install the ceiling support package or wall pass-through and “T” section package, firestops (where needed), insulation shield, roof flashing, chimney cap, etc. Maintain proper clearance to the structure as recommended by the manufacturer. The chimney must be the required height above the roof or other obstructions for safety and proper draft operation.

Note: If you are using a horizontal connector (refer to Figure 26), the chimney connector should be as high as possible while still maintaining the 18” (475 mm) minimum distance from the horizontal connector to the ceiling.

26

Page 26
Image 26