Initial Installation

Initial Installation

QUALIFIED INSTALLERS ONLY

WARNING: Operation of this heater when not connected to a properly installed and maintained venting system can result in carbon monoxide (CO) poisoning and possible death.

PREPARATION FOR INSTALLATION:

Remove the packaging from the appliance, and check to make sure there is no damage. If damage is found, please report it to both the carrier and your dealer as soon as possible.

Before beginning, carefully check the glass door and the log set

Locate a position where the flue system of the stove can be properly installed without damaging the integrity of the building; e.g. cutting a wall or ceiling joist.

Check stove and flue system clearance requirements.

Locate the stove where it can be accessed by a gas supply line.

Locate the stove in a large and open room that is centrally located in the house. This will optimize heat circulation and comfort.

As the stove can be equipped with a convection fan, ensure that an electrical outlet is within 6 ft (1.8 m) of the stove.

The flow of combustion and ventilation air must not be obstructed.

CLEARANCES TO COMBUSTIBLES:

CLEARANCES MUST BE SUFFICIENT TO ALLOW ACCESS FOR MAINTENANCE AND SERVICE.

Table 3: Clearance to Walls in an Open Area, refer to Figure 23.

Letter

 

Description

 

Clearance

 

 

A

 

Sidewall to unit

 

11 inches

(279 mm)

B

 

Backwall to unit

 

2.5 inches

(64 mm)

 

 

 

 

 

 

 

 

 

C

 

Corner to unit

 

2.5 inches

(64 mm)

 

 

 

 

 

 

 

 

 

D

 

Ceiling to floor

 

90 inches

(2286 mm)

 

 

 

 

 

 

 

 

E

 

Floor (on hardwood

0 inches

(0 mm)

 

 

 

and linoleum)

 

 

 

 

 

 

 

 

Table 4: Clearance to Walls in an Alcove

 

 

 

 

 

 

 

 

 

 

Description

 

Clearance

 

 

 

 

 

Minimum Width

 

431⁄2 inches (1105 mm)

 

 

 

Minimum Height

 

48 inches

(1219 mm)

 

 

 

Maximum Depth

 

24 inches

(610 mm)

 

 

 

 

 

 

 

 

 

 

 

 

Back Wall

B

 

 

Wall

 

 

Side

A

 

 

 

 

Adjacent Wall

 

 

C

Adjacent Wall

 

 

 

C

 

Figure 23: Clearance to Walls in an Open

Area, refer to Table 3.