Wire Size

Initial Installation

QUALIFIED INSTALLERS ONLY

ELECTRICAL REQUIREMENTS FOR GAS VALVE AND OPTIONAL BLOWER:

The ENVIRO CARA will operate without electrical power. This model has a millivolt gas control, which uses the pilot flame to generate enough electricity to operate the main burners. The appliance, when equipped with a blower, must be electrically connected and grounded in accordance with local codes or in the absence of local codes, with the current CSA C22.1 CANADIAN ELECTRICAL CODE Part 1, SAFETY STANDARDS FOR ELECTRICAL INSTALLATIONS, OR THE NATIONAL ELECTRICAL CODE ANSI / NFPA 70 in the U.S. When installing the Optional Remote Control System for the valve and the blower, refer also to the REMOTE CONTROLS section, and to Figure 4.

Table 10: Recommended Thermostat

Wire Size.

Wire Size

Max. Length

 

 

 

14 gauge

100 ft

(30.48 m)

 

 

 

16 gauge

60 ft

(18.29 m)

 

 

 

18 gauge

40 ft

(12.00 m)

20 gauge

25 ft

(7.62 m)

22 gauge

18 ft

(5.49 m)

 

 

 

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.

 

ON/OFF

 

 

Optional

Burner Switch

 

 

Remote

Blue

Thermocouple

Control

 

Thermopile

 

Purple

 

 

Inlet

Manifold

 

Pressure

 

 

Tap

 

Pressure Tap

 

 

 

Gas Control

 

Grey

Valve

 

 

 

 

 

70 ° F

Optional

 

 

 

Wall Switch

 

 

UP

Pilot Adjustment

 

 

DOWN

Screw

 

 

COOL / HEAT

 

 

PROGRAM

 

 

 

Optional

 

 

 

Thermostat

 

 

Figure 50: Gas Control Valve and Optional Thermostat Wiring.

WARNING: Electrical grounding instructions. This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard, and must be plugged directly into a properly grounded three-prong outlet.

DO NOT cut or remove the grounding prong from this plug.

ELECTRICAL INFORMATION:

Canadian Installations

The venting system must be installed in accordance with the current CSA B149 installation code and/or local codes having jurisdiction.

U.S.A. Installations

The venting system must be installed in accordance with the current National Fuel Gas Code, ANSI Z223.1, and/or local codes having jurisdiction.

Power

 

Black

 

 

Cord

White

Green/White

 

 

 

Black

 

 

 

Snap Disk N/O

Green/Yellow

Black

 

 

 

 

Fan

Black

Rheostat

 

 

Black

Figure 51: Wiring Diagram for Electric Fan.