Specifications

Specifications

Base Unit and Sensor Specifications

The following table lists the specifications for the EA800 base unit, sensors, and accessories.

Table 14

Specifications

 

 

 

 

 

 

Item

 

Specification

 

 

 

Dimensions

 

Approximately 230 mm x 199 mm x 55 mm(“9.375 H x 8.125" W x 2.25" D)

 

 

 

 

Weight

 

 

Base Unit: 0.27 kg (0.6 lb.)

 

 

Wireless Sensors: 0.11 kg (0.26 lb.) with batteries

 

 

 

 

 

 

 

 

 

 

The EA800 base unit is mountable directly to 3-gang standard electrical enclo-

Mounting

 

 

sure using pre-drilled holes on the EA800 rear case.

 

 

The EA800 base unit and wireless sensors can be mounted to drywall or simi-

 

 

 

 

 

 

lar surfaces using the appropriate anchors (not included).

 

 

 

Case Material

 

ABS, UL94V-0 rated

 

 

 

 

 

 

 

+11 to +26VDC @ 500mA current draw. Standard commercial filtered and

 

 

 

regulated power supply suitable. Supplied by AC adapter (not included; see

EA800 Input (Operating) Volt-

 

Accessories) or alarm panel.

 

 

age 1, 2, 3

 

 

Note: Power supply requirement does not include additional require-

 

 

 

 

 

 

ments for loads switched through alarm output relays where

 

 

 

power is derived from EA800 EA400 terminal strip connections.

 

 

 

 

EA800 Aux Power Out

 

Equivalent to DC input voltage used: +11 to +26VDC

 

(Maximum output current 0.5A).

 

 

 

 

 

 

EA800 Real-Time Clock Battery

 

CR2032 (3V Cell)

 

 

 

 

 

 

 

Either:

Wireless Sensor Input Voltage

 

• +12VDC @ <100mA current draw using a 2.1 mm barrel plug, center

 

positive; OR

 

 

 

 

 

 

• 2xAA Alkaline Batteries (1.5V Cell)

 

 

 

Wireless Sensor Radiating

 

• EA800 base unit: -3.5 dBm

Power (minimum, at PCB

 

• Sensors: -2.5 dBm

antenna connector)

 

 

 

 

 

Wireless Sensitivity:

 

• EA800: -94.5 dBm

(minimum at printed circuit

 

• Sensors: -95.5 dBm

board antenna connection)

 

 

 

 

Low and High Limit Adjust Range:

(Winland thermistor sensors only)

 

 

 

 

 

Temperature:

 

-80° C to 150° C

 

 

 

(-112° F to 302° F)

 

 

 

Note: The Low and High Limit Adjust Range is dependent upon the

 

 

 

sensor being used. See “Accessories” on page 44.

 

 

 

 

 

Humidity:

 

5 to 95% RH

 

 

 

Note: The Low and High Limit Adjust Range is dependent upon the

 

 

 

sensor being used. See “Accessories” on page 44.

 

 

 

 

 

Water Presence:

 

No Alarm / Alarm

 

 

 

 

Sensors

 

 

Up to four wired sensors

 

 

Up to four wireless sensors

 

 

 

 

 

 

Cable Length to Wireless

 

 

Multi-Function Sensor

 

100 ft. maximum

EA-WMFS

 

 

 

 

 

 

Wired Temperature Sensor:

 

2-wire; maximum 304 m (1000 ft.) cabling length

 

 

 

Wired Humidity Sensor:

 

3-wire; maximum 304 m (1000 ft.) cabling length

 

 

 

 

D-011-0152

73

Page 77
Image 77
Enviro EA800 owner manual Base Unit and Sensor Specifications