ENVISION RESIDENTIAL INSTALLATION MANUAL
Operation Logic Data
OPERATION LOGIC |
| HEATING |
| COOLING | FAN ON | SL1 - IN ON | |||
|
|
|
|
|
| ||||
STG1 | STG2 | STG3 | EMERG | STG1 | STG2 | ||||
|
|
| |||||||
|
|
|
|
|
|
|
|
| |
SINGLE SPEED UNITS |
|
|
|
|
|
|
|
| |
Compressor | On | On | On | Off | On | On | - | - | |
ECM2 Normal | Med | High | High | High | Med | High | Low | - | |
ECM2 Dehumidify | Med | High | High | High | 85% Med | 85% High | Low | - | |
PSC | On | On | On | On | On | On | On | - | |
Rev Valve | Off | Off | Off | Off | On | On | - | - | |
Loop Pump | On | On | On | Off | On | On | - | On | |
DHW Pump | On | Off | Off | Off | On | On | - | - | |
Aux Heater | Off | Off | Staged | Staged | Off | Off | - | - | |
Secondary 1- Out | On | On | On | Off | On | On | - | - | |
Emerg LED | Off | Off | Off | On | Off | Off | Off | - | |
Y1 | Y1, Y2 | Y1, Y2, W | W | Y1, O | Y1, Y2, O | G | - | ||
DUAL CAPACITY UNITS |
|
|
|
|
|
|
|
| |
On | Off | Off | Off | On | Off | - | - | ||
Off | On | On | Off | Off | On | - | - | ||
ECM2 Normal | Med | High | High | High | Med | High | Low | - | |
ECM2 Dehumidify | Med | High | High | High | 85% Med | 85% High | Low | - | |
Rev Valve | Off | Off | Off | Off | On | On | - | - | |
Loop Pumps | On | On | On | Off | On | On | - | On | |
DHW Pump | On | On | Off | Off | On | On | - | - | |
Aux Heater | Off | Off | Staged | Staged | Off | Off | - | - | |
Secondary 1- Out | On | On | On | Off | On | On | - | - | |
Secondary 2- Out | Off | On | On | Off | Off | On | - | - | |
Emerg LED | Off | Off | Off | On | Off | Off | - | - | |
Y1 | Y1, Y2 | Y1, Y2, W | W | Y1, O | Y1, Y2, O | G | - |
34