Envision Peripherals R-410A Vertical Dimensional Data, Top Air Discharge, Left Return, Left Side

Models: R-410A

1 40
Download 40 pages 13.59 Kb
Page 18
Image 18
Vertical Dimensional Data

ENVISION RESIDENTIAL INSTALLATION MANUAL

Vertical Dimensional Data

Top Air Discharge

LEFT RETURN

RIGHT RETURN

2ft [61cm]

Primary Service Access

Q

 

 

 

 

L

O

M

R

N

 

 

 

 

TOP

 

C

 

 

 

 

 

B

 

PTop Air DischargeLEFT RETURN O

L

N

TOP

T

T

S

S

B

Q

R

 

 

 

 

1.9in

 

 

[4.8cm]

1.9in

 

 

[4.8cm]

 

 

K J I

A

D E H F G

C

 

FRONT

 

 

 

LEFT SIDE
RIGHT SIDE

 

 

Overall Cabinet

 

 

 

Water Connections

 

Electrical Knockouts

 

Discharge Connection

 

 

Return Connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vertical

 

 

 

 

 

 

 

 

 

 

I

J

K

 

duct flange installed (±0.10 in)

 

 

using std deluxe filter rack (±0.10 in)

 

Models

A

B

C

D

E

F

G

H

Loop

 

1/2" cond

1/2" cond

3/4" cond

L

M

N

O

P

Q

R

S

 

T

 

 

 

Width

Depth

Height*

In

Out

HWG In

HWG

Cond-

Water FPT

HWG FPT

Low

Ext Pump

Power

 

 

Supply

Supply

 

 

Return

Return

 

 

 

 

 

Out

ensate

Voltage

Supply

 

 

Width

Depth

 

 

Depth

Height

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

022-030

in.

22.5

26.5

48.5

2.0

7.0

13.5

16.5

10.2

1" Swivel

1" Swivel

8.5

10.4

11.8

6.1

0.8

14.0

14.0

4.4

1.7

22.2

26.0

 

1.7

 

cm.

57.2

67.2

123.2

5.0

17.7

34.2

41.8

26.0

21.6

26.4

29.8

15.5

2.1

35.6

35.6

11.1

4.2

56.3

66.0

 

4.4

 

 

 

 

 

 

036-038

in.

25.6

31.6

50.4

2.3

7.3

15.9

18.9

10.6

1" Swivel

1" Swivel

8.0

11.3

12.8

6.9

1.1

18.0

18.0

3.8

1.7

28.1

26.0

 

1.7

 

cm.

65.0

80.2

128.0

5.7

18.4

40.3

47.9

26.8

20.3

28.6

32.4

17.5

2.8

45.7

45.7

9.6

4.4

71.2

66.0

 

4.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

042-049

in.

25.6

31.6

54.4

2.3

7.3

15.9

18.9

10.6

1" Swivel

1" Swivel

8.0

11.3

12.8

6.9

1.1

18.0

18.0

3.8

1.7

28.1

30.0

 

1.7

 

cm.

65.0

80.2

138.2

5.7

18.4

40.3

47.9

26.8

20.3

28.6

32.4

17.5

2.8

45.7

45.7

9.6

4.4

71.2

76.2

 

4.3

 

 

 

 

 

 

060-072

in.

25.6

31.6

58.4

2.3

7.3

15.9

18.9

10.6

1" Swivel

1" Swivel

8.0

11.3

12.8

6.9

1.1

18.0

18.0

3.8

1.7

28.1

34.0

 

1.7

 

cm.

65.0

80.2

148.3

5.7

18.4

40.3

47.9

26.8

20.3

28.6

32.4

17.5

2.8

45.7

45.7

9.6

4.4

71.2

86.4

 

4.3

 

 

 

 

 

 

Condensate is 3/4" PVC female glue socket and is switchable from side to front

 

 

 

 

 

 

 

 

 

 

 

 

 

Rev.: 07/19/06 B

Vertical unit shipped with deluxe 2" (field adjustable to 1") duct collar/filter rack extending from unit 3.25" and is suitable for duct connection.

 

 

 

 

 

 

 

 

 

 

 

Discharge flange is field installed and extends 1" [25.4 mm] from cabinet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Decorative molding and water connections extend 1.2" [30.5mm] beyond front of cabinet.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

Page 18
Image 18
Envision Peripherals R-410A Vertical Dimensional Data, Top Air Discharge, Left Return, Right Return, Left Side, Front