Envision Peripherals R-410A installation manual Unit Operating Parameters, Dual Capacity Models

Models: R-410A

1 40
Download 40 pages 13.59 Kb
Page 36
Image 36
Dual Capacity Models

ENVISION RESIDENTIAL INSTALLATION MANUAL

Unit Operating Parameters

Dual Capacity Models

FIRST STAGE OPERATION

 

 

 

 

Cooling -- No Desuperheater

 

 

Entering Water

Water Flow

Suction

Discharge

 

 

Water Temp

Air Temp Drop

Temp °F

GPM/Ton

Pressure PSIG

Pressure PSIG

Superheat

Subcooling

Rise °F

°F DB

50

1.5

125-140

205-225

12-20

8-14

17-21

17-23

3.0

120-135

190-210

12-20

8-14

8-12

17-23

 

70

1.5

135-145

280-290

10-16

8-14

16-20

17-23

3.0

133-143

250-260

10-16

8-14

9-13

17-23

 

90

1.5

142-152

345-355

8-12

8-14

14-20

17-23

3.0

140-150

330-340

8-12

8-14

8-12

17-23

 

 

 

 

 

Heating -- No Desuperheater

 

 

Entering Water

Water Flow

Suction

Discharge

 

 

Water Temp

Air Temp Rise

Temp °F

GPM/Ton

Pressure PSIG

Pressure PSIG

Superheat

Subcooling

Drop °F

°F DB

30

1.5

76-84

280-295

8-12

3-10

5-9

12-16

3.0

80-88

285-300

8-12

3-10

3-7

14-18

 

50

1.5

100-115

310-330

10-14

3-10

7-11

18-22

3.0

105-120

315-335

10-14

3-10

5-9

20-24

 

70

1.5

135-150

325-350

12-16

3-10

8-12

24-28

3.0

140-155

330-355

12-16

3-10

6-10

22-30

 

SECOND STAGE OPERATION

 

 

 

 

Cooling -- No Desuperheater

 

 

Entering Water

Water Flow

Suction

Discharge

 

 

Water Temp

Air Temp Drop

Temp °F

GPM/Ton

Pressure PSIG

Pressure PSIG

Superheat

Subcooling

Rise °F

°F DB

50

1.5

130-140

215-235

12-20

8-14

16-22

17-23

3.0

128-138

190-210

12-20

8-14

8-12

17-23

 

70

1.5

138-148

280-310

10-16

10-16

15-21

17-23

3.0

136-146

250-280

10-16

8-14

7-13

17-23

 

90

1.5

145-155

350-380

9-14

10-16

14-20

17-23

3.0

143-153

320-350

9-14

8-14

6-10

17-23

 

 

 

 

 

Heating -- No Desuperheater

 

 

Entering Water

Water Flow

Suction

Discharge

 

 

Water Temp

Air Temp Rise

Temp °F

GPM/Ton

Pressure PSIG

Pressure PSIG

Superheat

Subcooling

Drop °F

°F DB

30

1.5

73-85

270-305

8-14

3-10

6-10

15-21

3.0

77-90

280-315

8-14

3-10

4-8

17-23

 

50

1.5

97-110

290-325

10-16

3-10

9-13

22-28

3.0

102-115

300-335

10-16

3-10

7-11

24-30

 

70

1.5

130-145

320-355

13-19

3-10

10-14

30-36

3.0

135-150

325-360

13-19

3-10

8-12

32-38

 

Note: Cooling performance based on entering air temperatures of 80º F DB, 67º F WB.

Heating performance based on entering air temperature of 70º F DB.

36

Page 36
Image 36
Envision Peripherals R-410A Unit Operating Parameters, Dual Capacity Models, First Stage Operation, Second Stage Operation