Selecting a Font

Escape Sequence:

ESC

DLE

f

n

Hexadecimal:

1B

10

66

n

This command allows you to access type styles not specifically supported by an emulation.

This command selects the font designated by the variable n, where n can range from 0 through 254 decimal as follows:

Font

ID No.

 

 

 

Courier

0

 

Prestige Elite

1

 

OCR A

3

 

OCR B

4

 

Gothic

5

 

Presentor

6

 

PostNet

7

 

 

 

 

Note: Using any value other than the valid font ID number for n, causes the printer to accept and ignore the command, and cause a

FONT NOT AVAILABLE ERROR.

Selecting a Font’s HMI

Escape sequence: ESC DLE H

Hexadecimal: 1B 10 48

This command enables you to access natural pitches of a font that may not be specifically supported by an emulation. The command sets horizontal motion index (HMI) to the currently selected font’s HMI.

The command cancels the double-width print mode, but does not cancel the oversize-character (scalable characters) command. This command resets the Epson variable spacing to zero.

Character Sets and Global Commands 3-25