Parallel Interface Timing Requirements (continued)

Item

Ref.

Timing Requirements

 

f

Trailing edge must occur before the host

 

 

can strobe the next character into the

 

 

receive buffer. For normal write cycles

 

 

(receive buffer not full), this occurs at 10 μs

 

 

min., 500 μs nom., and 1000 μs max. after

 

 

the leading edge of STROBE-.

DATA1-8

g

The host writes the next character to the

 

 

interface. This can occur at any time

 

 

after the data stabilization time and hold

 

 

time of the previous character have

 

 

elapsed. (See Reference items a-band

 

 

b-con the preceding page.)

STROBE-

h

The host places the next strobe pulse on

 

 

the interface to initiate the next character-

 

 

transfer operation.

 

 

 

Initialize Sequence

The initialize sequence is a host-generated power-up reset sequence. When the host activates INIT-, the printer performs the following sequence.

1.Interrupts any ongoing operation.

2.Assumes the offline state.

3.Executes the normal power-up self-test routine.

4.Returns to the online state.