EPSON Stylus PHOTO RX600/610, RX620/630 Revision C
Disassembly and Assembly Disassembly and Assembly of Other Parts 60
4.6 Disassembly and Assembly of Other Parts4.6.1 Damper Assembly
1. Panel Unit Removal. (p41)
2. Main Board Unit Removal. (p.61) (as needed)
3. Remove a screw that secures the damper assembly, and remove it from the middle
housing.
4.6.2 Stacker
1. Panel Unit Removal. (p41)
2. Scanner Unit Removal. (p42)
3. Middle Housing Removal. (p43)
4. Remove the stacker by sliding forward while pushing projected areas located right
stacker.
Figure 4-21. Damper Assembly Removal
Figure 4-22. Stacker Removal
For installing the damper assembly, close the slot cover, and follow
the conditions as shown oi the figure below:
Damper Assembly
C.B.P Tite 3x10,F/ZN
Tightening torque
:0.6 ± 0.1 N⋅m
Slot Cover
Stacker