Configuration Menu Functions

"Setting" menu

 

Advanced

Default setting

 

 

 

Progressive *1

(Setting is only possible when 525i or 625i component video signals are being input)

OFF :IP conversion is carried out for each field in the screen. This is ideal for using when viewing images with a large amount of movement.

ON :Interlaced (i) signals are converted into progressive (p) signals. This is ideal

for using when viewing still images.

Noise Reduction *1

(Setting is only possible when composite video signals or S-Video signals are being input.)

This suppresses interference in images and makes the images appear softer. If viewing images with little or no interferences, such as images from DVDs, it is recommended that you change this setting to "OFF".

Output Scaling *1

This changes the display area (the part of images projected).

When component video, RGB-video, composite video or S-Video signals

are being input

Normal (92% display) :Input signals are projected at the normal image size. TV images are displayed at 92% size.

Larger :Component video and RGB-video images are displayed at 100% size. Composite video and S-Video images are displayed at 95% size.

The areas at the top, bottom and sides of images that cannot normally be seen are inserted and projected. Interference may occur at the top or bottom of the images depending on the image signal.

When computer signals are being input

Normal (100% display) :Input signals are projected at the full image size. Smaller(95% display) :The edges of the images are truncated when projected.

Select this option if there is interference at the top or bottom of the images.

Setup Level *1

(Setting is only possible when component video signals are being input or when NTSC signals from composite video or S-Video are being input.)

If using products designed for destinations such as the United States or South Korea that have different black level (setup level) settings, use this function to obtain correct images. Check the specifications of the connected equipment when changing this setting.

OFF

OFF

Normal

Normal

0%

(Varies depending on country of purchase)

Screen

Default setting

Position *1

Use , , and to move the display position for images.

18

*1 The setting values are stored separately for each image source and signal type.