EXTERNAL CONTROL PROTOCOL WD031-1-3

 

 

4/18/2005

 

 

 

01

04

Wrong Number of Command Arguments

01

05

Invalid Subcommand

01

06

Invalid Command

01

07

Not Available During Standby (deprecated)

01

08

Requested data not available

01

09

External control command not yet implemented (possible

 

 

future implementation)

01

10

Not Available at This Time

01

11

Invalid Security Password

 

 

 

Response Format: ESCX01xx, where xx = Command response

Response 07 has been deprecated due to the new auto-on function. Whenever a valid command is received (with two exceptions), the system will automatically enter the “on” mode, if it is in standby. A client may still handle response 07, but it is no longer sent from the host for any reason.

Response 10 will be sent when a normally valid command is sent to the host, but it cannot be processed due to the system’s mode. For example, a database play will not be processed while the system is in setup or options mode, AutoBuilding a changer, etc. Note that a key press command will never return this response, as even audio transport keys (play, stop) have alternate functions in various modes.

Unsolicited status events can be sent to report the state changes of the Escient products. There are two currently defined message levels: 5 - track changes, and 10 - all (including 1- second playing time updates). Clients are registered at level 5 by default. Clients may change their message level using the ESCX7002 command. See the control commands section for instructions on how to resister and unregister for unsolicited status event levels.

Unsolicited Status Events

 

COMMAND

 

 

EVENT

 

 

EVENT DESCRIPTION

 

 

 

 

 

 

 

 

GROUP

 

 

NUMBER

 

 

 

 

 

 

 

 

 

 

02

 

01

 

Power status changed. When the system has booted into an off state

 

 

 

 

 

 

you will receive a “RDY” status indicating it is ready to be powered on

 

 

 

 

 

 

and from then on an “OFF” or an “ON “ status.

02

 

 

 

 

Event Format: ESCX02010010003xxx,

 

 

 

 

 

 

Where xxx = a 3 character string

 

 

 

 

 

 

“RDY” = when power is first applied and it boots into

 

 

 

 

 

 

 

the off state (standby mode) – ready for power on.

 

 

 

 

 

 

“ON “ = if power on turned on (GUI appears)

 

 

 

 

 

 

“OFF” = if power is off (standby mode) (Video out off)

02

 

02

 

Play Mode changed (normal, random, etc)

02

 

 

 

 

Event Format: ESCX02020010002xx,

 

 

 

 

 

 

Where xx = the new play mode

 

 

 

 

 

 

01

= normal

 

 

 

 

 

 

02

= repeat track

 

 

 

 

 

 

03

= repeat title

 

 

 

 

 

 

04

= repeat group