Service Interval: Daily

4.1.3Clean grass build-up under deck and check mower blades.

Service Interval: Daily

CAUTION

POTENTIAL HAZARD

Raising the mower deck for service or maintenance relying solely on mechanical or hydraulic jacks could be dangerous.

WHAT CAN HAPPEN

The mechanical or hydraulic jacks may not be enough support or may malfunction allowing the unit to fall, which could cause injury.

HOW TO AVOID THE HAZARD

DO NOT rely solely on mechanical or hydraulic jacks for support. Use adequate jack stands or equivalent support.

a)Disengage PTO.

b)Stop engine and wait for all moving parts to stop. Remove key or spark plug wire(s).

c)Raise deck, support properly using safety precautions.

d)Clean out any grass build-up from underside of deck and in deck discharge chute.

e)Inspect blades and sharpen or replace as required.

f)If blade removal is necessary, be careful for the sharp cutting edges of the blades.

g)Re-install the blades (if they were removed) and torque blade bolts to 75-85 ft/lbs (102-115 N-m). Be sure the spring disk washer cone is installed toward the bolt head (See Figure 5).

h)Remove jack stands (or equivalent support) and lower deck to ground.

FIGURE 5

(102-115 N-m)

BLADE BOLT INSTALLATION

4.1.4Check safety interlock system.

Service Interval: Daily

a)For your safety, your Exmark mower is equipped with Operator Presence Controls, referred to as (OPC). When either the PTO is engaged, or the transmission shifter lever is not in neutral and the operator removes both hands from the handles, the mower engine MUST stop.

b)To determine if the OPC is in operating condition, clear area of bystanders. Run the engine at one-third throttle, then with the drive levers and neutral lock latches in the “park brake” position, shift the transmission into gear and release the OPC levers – the engine MUST stop.

-18 -