Extreme Networks 8800 Series manual LEDs on the 700/1200 W AC PSU

Models: 8800 Series

1 180
Download 180 pages 30.86 Kb
Page 93
Image 93

Installing an Extreme Networks AC PSU

2For the AC power cord:

If you are replacing only the power supply and you will use the existing AC power cord for the new PSU, you do not need to unplug the AC power cord.

If you are removing and replacing an AC power cord:

Remove the power cord retaining bracket as described in “Disconnecting a BlackDiamond 8810 AC Power Cord” on page 127 or “Removing the BlackDiamond 8806 AC Power Cord Retainer Channel” on page 130.

Completely disconnect and remove the old power cord.

Connect the new AC power cord to the AC input on the front of the switch and then connect the opposite end of the AC power cord to the wall outlet.

After the cord is connected, re-install the power cord retaining bracket.

3Lift the handle on the PSU.

4Pull the handle of the PSU to disconnect the PSU from the power connector at the back of the power supply bay. Slide the PSU partway out of the bay.

5Wearing thermal protective gloves, place both hands underneath the PSU to support the weight as it is pulled out from the switch.

6To install a replacement PSU, follow the steps under “Installing the PSU” on page 91.

NOTE

Leave the ESD strap permanently connected to the switch, so that the strap is always available when you need to handle ESD-sensitive components.

LEDs on the 700/1200 W AC PSU

The front panel of the Extreme Networks 700/1200 W AC PSU provides status LEDs. Table 16 describes the LED activity.

Table 16: LEDs on the 700/1200 W AC PSU

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

 

 

 

 

 

 

 

Predictive Fail

Fail

PSU Condition

Green

Amber

Amber

 

 

 

 

 

 

 

 

 

 

Power supply AC outputs working normally

On

Off

Off

AC input power present/standby output on

Blinking

Off

Off

Current limit on 48 VDC output

On

Off

Blinking

Predictive failure

On

Blinking

Off

No input power to this PSU only

Off

Off

On

No input power to any PSU

Off

Off

Off

Power supply failure

Off

Off

On

 

 

 

 

 

 

 

 

 

 