Extron electronic MPS 601 manual  A X!*X& Edid 

Models: MPS 601

1 55
Download 55 pages 56.42 Kb
Page 33
Image 33

Command

ASCII Command

Response

Description

 

(host to switcher)

(switcher to host)

 

 

 

 

 

 

 

 

 

Information request

 

 

 

InX!Aflw0•AuswX1%VmtX#AmtX#]

General information

I

 

 

 

 

 

 

 

Video input (1-6), Audio input (1-

 

 

 

 

 

6), Autoswitch status, Video mute

 

 

 

 

 

status, Audio mute status.

Query model name

1I

 

 

MPS601]

 

 

Query part number

N

 

 

60-xxxx-xx]

60-1337-01

 

 

 

 

 

 

 

Query Firmware version

 

 

 

 

 

 

Query firmware version

Q/q

 

 

x.xx ]

Displays firmware version number to

 

 

 

 

 

the second decimal.

Query firmware version with

*Q/q

 

 

x.xx.xxxx ]

Displays firmware version and build

build

 

 

 

 

number to the fourth decimal.

 

 

 

 

 

 

 

EDID Minder

 

 

 

 

 

 

Assign EDID to specific input

EAX!*X&EDID}

EDIDAX!*X&]

X& = 1 to 64

View EDID assignment

E  X!

 EDID

}

X&]

X&

= 1 to 69

 

A 

 

 

 

Save display EDID to user

ESX&EDID}

X&]

X& = 66 to 69

location

 

 

 

 

 

 

View/Read EDID of input in hex

ER X!EDID }

X2)]

Read HEX data (as text) from

format

EN X!EDID }

X*]

currently selected EDID.

View EDID native resolution

Read native resolution and refresh

 

 

 

rate from currently selected EDID. Example: 1920x1200@60Hz

NOTES: X! = Video Input

1 to 6 for single input addressing, 0=deselected.

X# = Mute status

0= off/disabled, 1=on/enabled

X& = EDID memory slot number

From lookup table (see User assigned EDID Mode on page 16):

 

1-64= factory EDIDs,

 

65 = Output (autodetect),

 

66-69= user loaded EDID slots.

 

Default: Video inputs 1 and 2=14

X* = Native resolution and refresh

Video inputs 3 to 6=56.

 

rate from EDID

 

X2) = EDID hex value

EDID raw hex value: 128 or 256 Byte (text form)

 

 

MPS 601 • Remote Communication and Control 27