Rack Mounting

#10-32 Screw w/ Nylon Captive Cap Washer

Figure 38. Mounting the Switcher

Table or Wall Mounting

The table or wall mounting brackets extend approximately 1/4 inch (6.4 mm) above the top surface of the switcher enclosure allowing for an air space between the enclosure and the surface. Table or wall mount the switcher as follows:

1.Attach the table or wall mounting brackets to the switcher with the eight #8 machine screws (figure 37 on page 44).

2.Hold the switcher with the attached brackets against the underside of the table or other furniture, or against the wall. Mark the location of the screw holes of the bracket on the mounting surface.

3.Drill 3/32 inch (2 mm) diameter pilot holes, 1/4 inch (6.4 mm) deep in the mounting surface at the marked screw locations.

4.Insert #8 wood screws into the four pilot holes. Tighten each screw into the mounting surface until just less than 1/4 inch of the screw’s head protrudes.

5.Align the mounting screws with the slots in the brackets and place the switcher against the surface, with the screws through the bracket slots.

6.Slide the switcher slightly forward or back, then tighten all four screws to secure the switcher in place.