RS-232/Remote Control, cont’d

RS-232/Remote Control, cont’d

The A/V switchers’ rear panel Remote connectors (Figure 4-1) can be connected to the serial port output of a host device, such as a computer or control system, to an Extron IR 20 Universal SYS 4/8/10/AV remote control, or to a remote contact closure device. Other than the IR 20, remote communications with the switcher are via Extron’s Simple Instruction Set, Extron’s Windows-based control program, or pin-programmed in the case of a contact closure device.

5

1

1

5

9

6

6

9

Female

Male

Figure 4-1 — Remote connector pinout

The RS-232 protocol of the rear panel RS-232/Remote connector is 9600 baud, 1 stop bit, no parity, and no flow control. The connector has the following pin assignments:

Pin

RS-232

Contact closure

Function

1

In#1

Input #1

2

 

 

 

TX

Transmit data (-)

3

 

 

 

RX

Receive data (+)

 

 

 

 

4

In#2

Input #2

5

Gnd

Gnd

Signal ground

6

In#3

Input #3

7

In#4

Input #4

8

 

 

In#5

Input #5

9

In#6

Input #6

 

 

 

 

Simple Instruction Set Control

Host-to-interface communications

SIS commands consist of one or more characters per field. No special characters are required to begin or end a command character sequence. When a command is valid, the switcher executes the command and sends a response to the host device. All responses from the switcher to the host end with a carriage return and a line feed (CR/LF = RS-232 ), which signals the end of the response character string. A string is one or more characters.

Switcher-initiated messages

When a local event, such as a front panel operation or error condition, occurs, the switcher responds by sending a message to the host. The switcher-initiated messages are listed below:

(C)Copyright 1996, Extron Electronics AV Series, Vx.xxContact closure CnFunction

The switcher issues the copyright message and input selected message when it first powers on. Vx.xx is the firmware version number. Cn identifies the currently selected input, where n is the input number (input 1 is the power-up default in normal mode). The switcher also sends the CnSimple Instruction Set Control message whenever the selected input is changed using the front panel buttons.

Reconfig Host-to-interface communications

The switcher initiates this message when there is a change in an audio model’s audio gain setting.

Error responses

When the switcher receives a valid SIS command, it executes the command and sends a response to the host device. If the switcher is unable to execute the command because the command is invalid or it contains invalid parameters, the switcher returns an error response to the host. The error response codes are:

E01Switcher-initiated messages - Invalid input channel number (out of range)

E06Error responses - Invalid input channel change (auto-switch mode active)

E09Timeout - Invalid function (mode) parameter

E10Manual background - Invalid command

E13Manual background - Invalid value (out of range)

E14Manual background Illegal command for this configuration

Timeout

Pauses of 10 seconds or longer between command ASCII characters result in a timeout. The command operation is aborted with no other indication.