3.Mechanical loading — Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading.
4.Circuit overloading — Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.
5.Reliable earthing (grounding) — Reliable earthing of
Rack Mounting
The XPA 1002 or XPA 2001 can be mounted in a rack shelf using the optional
RSU 129 1U Universal rack shelf (Extron part
1.If feet were installed on the bottom of the amplifier, remove them.
2.• Place the amplifier on one half of the rack shelf.
•Align the front of the amplifier with the front of the shelf, and align the threaded holes on the bottom of the amplifier with the holes in the rack shelf.
3.• Attach the amplifier to the rack shelf with the two provided
•Insert the screws from the underside of the shelf, and securely fasten them into
See the following illustration.
1U Universal Rack Shelf
1/2 Rack Width Front False
Faceplate
Front false faceplate uses 2 screws.
(2)
Use 2 mounting holes on opposite corners.
ATTENTION: Failure to follow these instructions may result in damage to the unit.
Using screws longer than 3/16” will damage the unit and void the warranty.
Figure 3. Rack Mounting of the Amplifier
4.Attach the false front panel (provided with rack shelf part
5.Attach the rack shelf to the rack using four
XTRA Series • Installation | 5 |