Extron electronic XPA1002, XPA2001-70V manual Bridged Mono Output, Bridging the Output of the XPA

Models: XPA2001-100V XPA1002 XPA2001-70V

1 29
Download 29 pages 28.16 Kb
Page 25
Image 25
Bridged Mono Output

Bridged Mono Output

The power output of the XPA 1002 can be effectively doubled by bridging the output. Bridging allows power to be output in mono at 200 watts at 8 ohms.

NOTES: The bridging instructions that follow apply only to the XPA 1002 model.

The minimum load impedance when bridging is 8 ohms.

To bridge the output, follow the steps and refer to the diagram below:

1.Unplug the IEC power cord from the power amplifier.

2.Fully attenuate the potentiometer.

3.Wire the output as shown in the following diagram.

4.Wire the input as shown in the following diagram.

5.Connect the IEC power cord and power up the amplifier.

6.Adjust the input levels of channels 1 and 2 identically.

See D (Attenuation) of “Rear Panel Features and Operation” on page 12 for more details.

100-240V x.yAMAX, 50-60Hz

XPA 1002

ATTENUATION

1

2

1

 

 

2

 

LIMITER/PROTECT

 

12 10

8

14

12 10

8

 

14

6

 

6

SIGNAL

 

 

4

 

 

4

 

 

2

 

 

2

 

 

 

0

 

 

0

INPUTS

1 2

 

REMOTE

 

G STANDBY

10V

50mA

V

C G

8Ω/4Ω OUTPUTS

12

CLASS 2 WIRING

Levels should be set identically.

3.5mm

Captive Screw

Balanced Wiring

1

 

From

2

Mono

 

Source

 

Un-Balanced Wiring

1

 

From

2

Mono

 

Source

 

5mm

Captive Screw

InputAmplified Output

To 8 Ohm Minimum Speaker Load Figure 10. Bridging the Output of the XPA 1002

1

 

2

NOTE: During bridged mono output, the + output

 

from output channel 1 becomes the positive

 

terminal and the + output from channel 2

 

becomes the negative terminal

Figure 10. Bridging the Output of the XPA 1002

XTRA Series • Operation

19

Page 25
Image 25
Extron electronic XPA1002, XPA2001-70V, XPA2001-100V manual Bridged Mono Output, Bridging the Output of the XPA