Convection cooled — The XTRA Series of amplifiers are convection cooled without the need for fans, ensuring quiet, reliable operation.

Ultra low inrush current - no need for power sequencing — Allows many XTRA Series amplifiers to be powered on simultaneously without overloading power circuits. This eliminates the need for power sequencing.

Flexible Conduit Adapter Kit, part # 70-228-02Suitable for use in other environmental air space in accordance with section 300.22, (C) of the

National Electrical Code only when used with optional Flexible Conduit Adapter Kit.

Auto-standby with fast power-upThe amplifiers automatically enter into a standby mode after 25 minutes of inactivity, + or - 5 minutes, dramatically reducing power consumption. They quickly return to full power status upon signal detection.

Rear panel attenuation (level) controls — Provide attenuation of input signals for setting proper audio system gain staging as well as two-zone applications. They are located on the rear panel to prevent unauthorized or accidental tampering of the level adjustments.

Multiple protection circuits — Activates during excessive clipping, output shorts, thermal overload, or DC faults to prevent damage to the amplifier and speakers.

Remote standby port — Enables the amplifiers to be remotely powered down when not in use, reducing operating cost.

Remote volume and mute control port — This port allows the amplifiers to be remotely controlled using the optional Extron VCM 100 Series volume and mute or VC 50 volume controllers.

Bridgeable outputs — The power output of the XPA 1002 can be effectively doubled by bridging the output. A mono source is wired to both the left and right input while the output is wired for bridged operation. Bridging allows power to be output at 200 watts into 8 ohms. The minimum load impedance when bridging is 8 ohms. See the wiring instructions beginning on page 19.

Front and rear-mounted signal and protection indication LEDs — Provide convenient indication of amplifier operation from both sides of an equipment rack.

Internal international power supply — The 100-240 VAC, 50-60 Hz universal power supply provides worldwide power compatibility.