Extron electronic XPA2001-100V, XPA2001-70V, XPA1002 manual Removing the IEC Connector

Models: XPA2001-100V XPA1002 XPA2001-70V

1 29
Download 29 pages 28.16 Kb
Page 14
Image 14
Figure 6. Removing the IEC Connector

100-

 

 

240V

1.3

z

 

A50-

 

 

60H

Remove screws

(both sides) to release IEC connector plate.

Blue Wire Brown Wire

N

L

 

 

Remove nut

Figure 6. Removing the IEC Connector

4.Remove the ground wire nut from the grounding stud on the bottom of the enclosure, as shown above.

5.Remove the 2 screws from the IEC plate, and remove the IEC connector plate and the attached wires through the rear panel of the XPA, as shown above.

6.Thread the 18-gauge power wires through the length of the electrical conduit tube.

7.Install the EMT adapter plate with conduit attached into the opening from which the IEC connector was removed in step 5.

8.Slide the conduit nut over the bundle of wires exiting the conduit and onto the conduit itself. Hand tighten the conduit nut to the conduit.

9.Attach the EMT adapter plate assembly to the XPA using the 2 screws that were removed in step 5.

10.Connect the black hot (line) and white neutral wires to the terminal block on the

PCB using the 2 screws that were removed in step 3. Use the included zip tie wrap to secure the two wires together close to the terminals. See the following illustration.

WARNING: Failure to follow these instructions may result in serious injury. Ensure that you observe correct wire polarity. The following illustration shows the location of the hot (L) and neutral (N) terminals.

Terminal Block

Zip-Tie

 

LINE

L

NEUTRAL

N

Conduit Nut

EMT Adapter Plate

Hot

Terminal (Black)

Neutral Terminal (White)

Ground

Wire Nut

Figure 7. Installing the EMT Adapter Plate Assembly

11.Connect the ground wire, as shown above, to the grounding stud on the bottom of the enclosure using the nut that was removed in step 4.

12.Replace the cover of the XPA by attaching the 8 screws that were removed in step 2.

XTRA Series • Installation