Remote Volume Control

Remote Volume Control

Options for remote control of the XPA amplifiers include the Extron VCM 100 and

VC 50 volume controllers. Third party 10k potentiometer volume controllers can also be connected to this port.

As shown in the following illustration, pin V (1) on the XPA is a 10 VDC reference voltage. Pin C (2) is the volume control DC voltage input. The range is 0 to 10 V, where 0 V is mute and 10 V provides maximum volume. Pin G (3) is ground.

NOTE: All nominal levels are at ±10%.

 

REMOTE

 

G STANDBY

10V

50mA

V

C G

 

Red

 

Black

or

Ground

10V ExtronManual backgroundManual background 50 mA

VOL/MUTE

1

2

3

4

5

STANDBY

Extron

STP 22

Cable

VOL/ MUTE 10V

VOLUME

MUTE

VCM 100

Figure 8. Pinout Diagram for VCM 100 MAAP Connection to XPA Remote Connector