FieldServer instruction manual FS-8700-21 LonWorks Manual

Models: FS-8700-21

1 62
Download 62 pages 42.76 Kb
Page 51
Image 51

 

FS-8700-21 LonWorks Manual

 

 

 

 

 

 

 

 

Page 51 of 62

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Data Length

 

 

 

 

 

 

 

1

 

 

 

 

 

 

Suggested Data Array Formats

 

 

 

 

 

Sint16, Float

 

 

SNVT_press_p

 

 

Data Item 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measurement

 

 

Units

 

 

Values Range

 

 

Invalid Value

 

 

 

 

 

 

Pressure (gauge)

 

 

Pascals

 

-32,768 .. 32,766

 

 

32,767 (0x7FFF)

 

 

 

 

 

Data Length

 

 

 

 

 

 

 

3

 

 

 

 

 

 

Suggested Data Array Formats

 

 

 

 

 

Uint16, Float

 

 

 

 

 

Data Item 1

 

 

 

 

 

 

 

 

priv_zn_action

 

 

 

 

 

 

Measurement

 

 

Units

 

 

Values Range

 

 

Invalid Value

 

 

 

 

 

 

privacyzone_t

 

 

N/A

 

0 .. 5

 

 

255 (0xFF)(PZ_NUL)

 

 

SNVT_privacyzone

 

 

Data Item 2

 

 

 

 

 

 

 

 

priv_zn_number

 

 

 

 

 

 

Measurement

 

 

Units

 

 

Values Range

 

 

Invalid Value

 

 

 

 

 

 

Zone number

 

 

Privacy zone number

 

1 .. 255

 

0

 

 

 

 

 

 

Data Item 3

 

 

 

 

 

 

 

 

priv_zn_camera_id

 

 

 

 

 

 

Measurement

 

 

Units

 

 

Values Range

 

 

Invalid Value

 

 

 

 

 

 

Camera ID

 

 

ID number

 

1 .. 65,535

 

0

 

 

 

 

 

 

Data Length

 

 

 

 

 

 

 

6

 

 

 

 

 

 

Suggested Data Array Formats

 

 

 

 

 

Float

 

 

 

 

 

Data Item 1

 

 

 

 

 

 

 

 

ptz_pan_dir

 

 

 

 

 

 

Measurement

 

 

Units

 

 

Values Range

 

 

Invalid Value

 

 

 

 

 

 

ptz_pan_dir

 

 

Direction

 

0 .. 255

 

 

N/A

 

 

 

 

 

Data Item 2

 

 

 

 

 

 

 

 

ptz_pan_speed

 

 

 

 

 

 

Measurement

 

 

Units

 

 

Values Range

 

 

Invalid Value

 

 

 

 

 

 

Pan speed

 

 

Percent of full level

 

0.0 .. 100.0

 

 

N/A

 

 

 

 

 

Data Item 3

 

 

 

 

 

 

 

 

ptz_tilt_dir

 

 

 

 

 

 

Measurement

 

 

Units

 

 

Values Range

 

 

Invalid Value

 

 

 

SNVT_ptz

 

 

tilt_dir_t

 

 

N/A

 

0 .. 2

 

 

255 (0xFF)(TILT_NUL)

 

 

 

 

 

Data Item 4

 

 

 

 

 

 

 

 

ptz_tilt_speed

 

 

 

 

 

 

Measurement

 

 

Units

 

 

Values Range

 

 

Invalid Value

 

 

 

 

 

 

Tilt speed

 

 

Percent of full level

 

0.0 .. 100.0

 

 

N/A

 

 

 

 

 

Data Item 5

 

 

 

 

 

 

 

 

ptz_zoom

 

 

 

 

 

 

Measurement

 

 

Units

 

 

Values Range

 

 

Invalid Value

 

 

 

 

 

 

zoom_t

 

 

N/A

 

0 .. 2

 

 

255 (0xFF)(ZOOM_NUL)

 

 

 

 

 

Data Item 6

 

 

 

 

 

 

 

 

ptz_zoom_speed

 

 

 

 

 

 

Measurement

 

 

Units

 

 

Values Range

 

 

Invalid Value

 

 

 

 

 

 

ptz_zoom_speed

 

 

Meters (m)

 

 

-3.40282E38 ..

 

N/A

 

 

 

 

 

 

 

 

 

 

 

3.40282E38

 

 

 

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web: www.fieldserver.com Tel: (408) 262 2299 Fax: (408) 262 2269 Toll Free: (888) 509 1970 email: support@fieldserver.com