20 | Installation (for qualified installers only) |
Wall Switch or Thermostat Installation
Wiring Diagram (Millivolt System)
Do not connect
The included wall switch may be installed following the directions below. An optional thermostat may also be installed. It is attached to the gas control valve in the same manner.
Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
On/Off Switch (on fireplace)
Red Brown
Thermocouple | Thermopile | Piezo Igniter |
Copper
Wire
Red
White
Orange
Spark Electrode
Pilot Hood
Optional Wall Switch,
Thermostat, or
Remote Control
Wall Switch Installation
1. Attach the included wire to the gas control valve.
Attach the two wires to the top and bottom posts on the gas control valve (orientation does not matter).
2.Determine a location for the wall switch (the wire is a maximum 25' long). Route the wire through the gas inlet hole (either side) to the junction box and attach following the directions below. Set the on/off switch on the appliance to "OFF" to control the appliance with the wall switch.
Insert the wire
a through the back of the mounted junction box (your junction box may look different). Expose 1/2" of each wire. Secure the wires to the posts on the side of the on/off switch (orientation does not matter).
From
Appliance
Standard
Screwdriver
Carefully pack the wires into the b junction box. Attach the switch
to the junction box. Attach the switchplate to the switch.
Standard
Screwdriver
© Travis Industries | 4080214 |