Installation (for qualified installers only)

9

Top Vent or Rear Vent Configuration

This appliance is shipped in the rear vent configuration. To change to the top vent configuration, follow the directions below.

NOTE: the vent configuration affects several aspects of installation (framing, maximum vent rise, maximum vent run). When reviewing the installation requirements make sure to pay attention to the type of configuration being used.

Converting the

Fireplace to Top Vent

Configuration

Remove the 4 screws securing the cover plate. Remove it and place it aside.

Fireplace

of

Top

ofFireplace Back

Remove the 4 screws

securing the cover plate (with

hole).

This part may be discarded.

Remove the 4 screws securing the intake cover plate. Remove it and place it aside.

Remove and discard all of the insulation found near the flue assembly (make sure to remove every piece).