26 Installation (for qualified installers only)
© Travis Industries 4080214 100-01182_003
Rear Vent Configuration with Horizontal Termination (no vertical rise)
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
and diffuser positions.
HINT: Travis Industries provides a minimum rear vent kit (sku 98900168). It includes a 4” section and
a horiztontal termination cap.
Optional 45° Elbow Termination
See the charts above to
determine maximum vent
3 feet
0 feet

0 feet

4' (max)

Exhaust Restrictor Removed
Intake Restrictor # 1 (stock)
Diffuser Position # 1 (stock)
Vent with No 45° Elbow
3 feet
0 feet

0 feet

2' (max)

Vent with 1 45° Elbow
Min. 4" Horizontal Section
Max. 24" Horizontal Section(s)
Min. 4" Horizontal Section
Max.48" Horizontal Section(s)
Exhaust Restrictor Removed
Intake Restrictor # 1 (stock)
Diffuser Position # 1 (stock)
If venting to the rear with no vertical
sections, remove and discard the exhaust
restrictor. Replace the screws in the same
holes.
Back Wall of
Firebox
Firebox
Roof
EXHAUST RESTRICTOR REMOVAL