26 | Installation (for qualified installers only) |
Rear Vent Configuration with Horizontal Termination (no vertical rise)
•The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and diffuser positions.
HINT: Travis Industries provides a minimum rear vent kit (sku 98900168). It includes a 4” section and a horiztontal termination cap.
Vent with No 45° Elbow
3 feet
0 feet
0feet | (max) |
| 4' |
•Exhaust Restrictor Removed
•Intake Restrictor # 1 (stock)
•Diffuser Position # 1 (stock)
•Min. 4" Horizontal Section
•Max.48" Horizontal Section(s)
Vent with 1 45° Elbow
3 feet
0 feet
0feet | (max) |
| 2' |
See the charts above to determine maximum vent
Optional 45° Elbow | Termination |
•Exhaust Restrictor Removed
•Intake Restrictor # 1 (stock)
•Diffuser Position # 1 (stock)
•Min. 4" Horizontal Section
•Max. 24" Horizontal Section(s)
EXHAUST RESTRICTOR REMOVAL
| Firebox | |
| Roof | |
Back |
|
|
Wall | of | |
Firebox |
|
If venting to the rear with no vertical sections, remove and discard the exhaust restrictor. Replace the screws in the same holes.
© Travis Industries | 4080214 |