Installation (for qualified installers only)

Mantel Requirements

The illustration below details mantel clearances and maximum mantel depth.

Any material that protrudes more than 3/4” from the non-combustible facing is considered a mantel and must meet the mantel requirements.

Mantel

(combustible or non-combustible)

 

 

Maximum Mantel Depth (b)

0”

1”

2”

3”

4”

5”

6”

7”

8”

9” 10” 11” 12”

18+”

 

 

 

 

 

 

 

 

 

17”

 

 

 

 

 

 

 

 

 

16”

 

 

 

 

 

 

 

 

 

15”

 

 

 

 

 

 

 

 

b

14”

 

 

 

 

 

 

 

 

a

13”

12” 11”

10”

Mantel 9” Height

Above 8”

Face (a) 7”

6” 36-3/4” 5” 4” 3” 2” 1” 0”

Base of the Fireplace

Combustible mantel columns (legs) that protrude more than 3/4” from the glass frame must meet the sidewall clearance. If they protrude 3/4” or less, they must meet the facing clearance (2-1/4” from the glass frame - to the side of the fireplace, not in front of it).

Non-combustible mantel columns do not have a minimum clearance.

Examples: • If you wish to have a 8” deep mantel, it must be at least 12-1/4” above the fireplace face (49” above the base).

• If you wish to have a mantel 8” above the fireplace face, it must be no deeper than 3-3/4”.