40 Installation (for qualified installers only)

© Travis Industries 4080214 100-01182_003

Mantel Requirements

The illustration below details mantel clearances and maximum mantel depth.

Any material that protrudes more than 3/4” from the non-combustible facing is considered a mantel

and must meet the mantel requirements.

Examples: If you wish to have a 8 deep mantel, it must be at least 12-1/4 above the fireplace face (49 above the base).
If you wish to have a mantel 8 above the fireplace face, it must be no deeper than 3-3/4.
Maximum Mantel Depth (b)
Mantel
Height
Above
Face (a)
0
1
2
8
7
6
5
4
3
9
0123456789101112
10
11
12
13
14
15
16
17
18+
36-3/4
a
b
Base of the Fireplace
Mantel
(combustible or non-combustible)
Combustible mantel columns (legs) that
protrude more than 3/4 from the glass
frame must meet the sidewall clearance. If
they protrude 3/4 or less, they must meet
the facing clearance (2-1/4 from the glass
frame - to the side of the fireplace, not in
front of it).
Non-combustible mantel columns do not
have a minimum clearance.